Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Mass Spectrom Adv Clin Lab ; 25: 12-18, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35694178

RESUMO

Introduction: Advances in liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) have enabled the quantification of immunosuppressants using microsampling techniques. In this context, dried matrix on paper discs (DMPD) could be a useful alternative to conventional venipuncture. Although analytical validation is necessary to establish the suitability of method performance, it is not sufficient to proceed with its implementation into routine clinical practice. Also necessary is that equivalence between sampling methods be demonstrated in a clinical validation study. Objetives: To clinically validate a LC-MS/MS method for the quantification of tacrolimus, sirolimus, everolimus and cyclosporin A using DMPD. Methods: According to the recommendations of international guidelines, at least 40 whole blood (WB) and DMPD paired samples for each analyte were collected by skilled technicians and analyzed using LC-MS/MS. Results were evaluated in terms of statistical agreement and bias values at medical decision points. Results: For all analytes, Passing-Bablok regression analysis revealed that confidence intervals (CIs) for slopes and intercepts included 1 and 0, respectively. It also showed that biases at medical decision points were not clinically relevant. No statistically significant differences between DMPD and WB were found using difference plots and agreement analysis. In this regard, CIs for bias estimators included 0, and more than 95% of the results fell within the limits of agreement. Conclusion: The feasibility of the clinical application of simultaneous quantification of tacrolimus, sirolimus, everolimus and cyclosporin A in DMPD was demonstrated. Results showed that this microsampling technique is interchangeable with conventional WB sampling when specimens are collected by trained personnel.

2.
Acta bioquím. clín. latinoam ; 56(2): 139-148, abr. 2022. graf
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-1402951

RESUMO

Resumen La ferritina es una proteína de gran tamaño que se encuentra fisiológicamente en el líquido cefalorraquídeo (LCR) en concentraciones de 2-10 ng/mL. Su elevación puede utilizarse como biomarcador en distintas condiciones patológicas. El procedimiento de validación tradicional para la medición en LCR no puede ser utilizado debido a la ausencia de controles y calibradores comerciales para esta matriz. El objetivo de este trabajo fue llevar a cabo una validación analítica de ferritina en LCR. Se realizaron ensayos de estimación de precisión y veracidad mediante el protocolo EP15-A3, linealidad por el protocolo EP6-A (ambos de la guía de la CLSI), recuperación, estabilidad, contaminación por arrastre, interferencia por hemólisis y bilirrubina y límite de detección (LoD). La ferritina en LCR en el autoanalizador DxI 800 de Beckman Coulter tuvo una performance intra e interensayo <3,7%, el ensayo denota linealidad en el intervalo de 2,1-547 ng/mL; se estableció estabilidad por un período de 5 días y la recuperación resultó ser aceptable. No se evidenció efecto de contaminación por arrastre ni interferencia por hemólisis hasta un rango entre 300-500 mg/dL de hemoglobina, ni interferencia por bilirrubina hasta una concentración de 16,0 mg/dL de bilirrubina total. El LoD fue de 0,4 ng/mL. Por medio de los ensayos realizados se logró validar la ferritina en LCR a partir de la utilización de pools de muestras, lo que pudo garantizar la confiabilidad y exactitud del método analítico.


Abstract Ferritin is a large protein physiologically present in the cerebrospinal fluid (CSF) in concentrations of 2-10 ng/mL. Its elevation can be used as a biomarker in several pathological conditions. The traditional validation procedure for measurement in CSF cannot be used due to the absence of commercial controls and calibrators for this matrix. The objective of the present study was to perform CSF ferritin analytical validation. Assays such as precision and accuracy estimation through the EP15-A3 protocol, linearity according to the EP6-A protocol (both from the CLSI guidelines), recovery, stability, carry-over, hemolysis and bilirubin interference and limit of detection (LoD) were conducted. Serum samples with different concentrations of ferritin were added to aliquots of a normal CSF pool. CSF ferritin in the Beckman Coulter DxI 800 had a <3.7% intra and inter-assay performance, the assay shows linearity in the 2.1 -547 ng/mL interval, stability was established for a 5-day period and the recovery was acceptable. There was neither carry-over effect or hemolysis interference up to a range of 300-500 mg/dL of hemoglobin, nor interference by bilirubin up to 16.0 mg/dL of total bilirubin. The LoD was 0.4 ng/mL. By means of the performed assays, CSF ferritin was validated by using sample pools, thereby ensuring the reliability and accuracy of the analytical method.


Resumo A ferritina é uma grande proteína fisiologicamente encontrada no líquido cefalorraquidiano (LCR) em concentrações de 2 a 10 ng/mL. Sua elevação pode ser usada como biomarcador em diferentes condições patológicas. O procedimento de validação tradicional para medição no LCR não pode ser usado devido à ausência de controles e calibradores comerciais para esta matriz. O objetivo deste estudo foi realizar uma validação analítica da ferritina no LCR. Foram realizados estudos de precisão e veracidade utilizando o protocolo EP15-A3, linearidade pelo protocolo EP6-A (ambos das diretrizes do CLSI), recuperação, estabilidade, contaminação transportada, interferência de hemólise e bilirrubina e limite de detecção (LoD). A ferritina no LCR no DxI 800 da Beckman Coulter teve um desempenho intra e inter-ensaio <3,7%, o ensaio denota linearidade na faixa de 2,1-547 ng/mL, a estabilidade foi estabelecida em um período de 5 dias e a recuperação foi considerado aceitável. Nenhum efeito de transporte ou interferência por hemólise foi evidenciado até um intervalo entre 300-500 mg/dL de hemoglobina, nem interferência pela bilirrubina até uma concentração de 16,0 mg/dL de bilirrubina total. O LoD foi de 0,4 ng/mL. Através dos testes realizados, a ferritina no LCR foi validada, com base no uso de pool de amostras, o que poderia garantir a confiabilidade e a acurácia do método analítico.


Assuntos
Líquido Cefalorraquidiano , Ferritinas , Bilirrubina , Hemoglobinas , Proteínas , Remoção , Ensaio , Soro , Eficiência , Poluição Ambiental , Hemólise , Métodos
3.
J Mass Spectrom Adv Clin Lab ; 19: 7-19, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34820661

RESUMO

INTRODUCTION: Due to its high specificity and sensitivity, liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is the gold standard method for immunosuppressant quantification in therapeutic drug monitoring. In this context, dried blood spots (DBS) have become a promising strategy as a sample collection procedure. Although the advantages of DBS over venipuncture are well known, this approach has limitations that strongly influence the acceptance of analytical results. Among them, the most important is hematocrit (Ht). The easiest way of overcoming this problem is by analyzing complete spots. In this strategy, called dried matrix on paper discs (DMPD), blood is volumetrically applied on pre-punched discs. OBJECTIVES: To validate an LC-MS/MS method for the quantification of tacrolimus, sirolimus, everolimus and cyclosporin A using DMPD. METHODS: The procedure was validated according to international guidelines using a commercial kit. The following performance parameters were evaluated: selectivity, carryover, linearity, accuracy, precision, lower limit of quantitation, relative recovery, commutability and stability. In addition, a method comparison study was performed to evaluate the clinical influence of Ht on the results. RESULTS: All performance parameters were within acceptance criteria and, hence, it was determined that the validated method is fit for the intended purpose. Likewise, calculated bias values on medical decision levels showed that there was no clinical influence of Ht on the results. CONCLUSION: Unlike other similar methodologies that have been published, here, a simple method has been fully validated. This is the first LC-MS/MS methodology adapting a commercial kit to use DMPD as a sampling strategy.

4.
J Proteome Res ; 20(1): 841-857, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33207877

RESUMO

A discovery-based lipid profiling study of serum samples from a cohort that included patients with clear cell renal cell carcinoma (ccRCC) stages I, II, III, and IV (n = 112) and controls (n = 52) was performed using ultraperformance liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry and machine learning techniques. Multivariate models based on support vector machines and the LASSO variable selection method yielded two discriminant lipid panels for ccRCC detection and early diagnosis. A 16-lipid panel allowed discriminating ccRCC patients from controls with 95.7% accuracy in a training set under cross-validation and 77.1% accuracy in an independent test set. A second model trained to discriminate early (I and II) from late (III and IV) stage ccRCC yielded a panel of 26 compounds that classified stage I patients from an independent test set with 82.1% accuracy. Thirteen species, including cholic acid, undecylenic acid, lauric acid, LPC(16:0/0:0), and PC(18:2/18:2), identified with level 1 exhibited significantly lower levels in samples from ccRCC patients compared to controls. Moreover, 3α-hydroxy-5α-androstan-17-one 3-sulfate, cis-5-dodecenoic acid, arachidonic acid, cis-13-docosenoic acid, PI(16:0/18:1), PC(16:0/18:2), and PC(O-16:0/20:4) contributed to discriminate early from late ccRCC stage patients. The results are auspicious for early ccRCC diagnosis after validation of the panels in larger and different cohorts.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Biomarcadores Tumorais , Carcinoma de Células Renais/diagnóstico , Diagnóstico Precoce , Humanos , Neoplasias Renais/diagnóstico , Lipidômica , Aprendizado de Máquina , Espectrometria de Massas
5.
Acta bioquím. clín. latinoam ; 54(1): 61-68, mar. 2020. graf, tab
Artigo em Espanhol | LILACS | ID: biblio-1130580

RESUMO

El uso de bisfenol-A (BPA) a nivel de la industria global se ha venido incrementando en los ultimos anos, y fueron los mercados emergentes los impulsores de esta demanda creciente. Las aplicaciones de BPA en la industria de los alimentos y bebidas representan solo del 3 al 4% del consumo global de policarbonato, pero su uso esta siendo reexaminado debido a que se conocieron varios trabajos cientificos que indican la existencia de una relacion directa entre el BPA y los efectos adversos para la salud. La contaminacion de los alimentos y bebidas se produce por migracion del BPA desde los envases que los contienen (alimentos enlatados, vinos, etc.), y es la principal fuente de exposicion en el humano. Para evaluar dicha exposicion se desarrollo y valido un metodo analitico por cromatografia gaseosa acoplada a espectrometria de masa para la cuantificacion de BPA total en orina de mujeres embarazadas atendidas en el Hospital Italiano de Buenos Aires en el ano 2013, con un limite de cuantificacion de 2,0 ng/mL y un limite de deteccion de 0,8 ng/mL. De las 149 muestras de orina analizadas, el 66,4% fueron cuantificables, con la mediana de BPA total de 4,8 ng/mL (4,3 ng/mg de creatinina) y la media geometrica de 4,8 ng/mL (4,7 ng/mg de creatinina).


The use of bisphenol-A (BPA) at the level of the global industry has been increasing in recent years, with emerging markets being the drivers of this growing demand. BPA applications in the food and beverage industry represent only 3 to 4% of the global consumption of polycarbonate, but its use is being reexamined because several scientific works were reported indicating the existence of a direct relationship between BPA and adverse effects on health. The contamination of food and beverages is produced by the migration of BPA from the containers that hold them (canned foods, wines, etc.) and it is the main source of exposure in humans. To evaluate this exposure, an analytical method was developed by gas chromatography coupled to mass spectrometry for the quantification of total BPA in urine of pregnant women treated at the Hospital Italiano de Buenos Aires in 2013, with a limit of quantification of 2.0 ng/mL and of detection of 0.8 ng/mL. Of the 149 urine samples analyzed, 66.4% were quantifiable, with a median total BPA of 4.8 ng/mL (4.3 ng/mg creatinine) and a geometric mean of 4.8 ng/mL (4.7 ng/mg creatinine).


O uso de bisfenol-A (BPA) ao nivel da industria global foi aumentando nos ultimos anos, e foram os mercados emergentes que deram impulso a essa demanda crescente. As aplicacoes de BPA na industria de alimentos e bebidas representam apenas 3 a 4% do consumo global de policarbonato, mas seu uso esta sendo reexaminado visto que varios trabalhos cientificos indicando a existencia de uma relacao direta entre o BPA e os efeitos adversos na saude foram conhecidos. A contaminacao dos alimentos e bebidas e produzida pela migracao de BPA das embalagens que os contem (alimentos enlatados, vinhos, etc.) e e a principal fonte de exposicao em humanos. Para avaliar esta exposicao, foi desenvolvido e avaliado um metodo analitico por cromatografia gasosa acoplada a espectrometria de massas para a quantificacao do BPA total na urina de gestantes atendidas no Hospital Italiano de Buenos Aires em 2013, com um limite de quantificacao de 2,0 ng/mL e um limite de deteccao de 0,8 ng/mL. Das 149 amostras de urina analisadas, 66,4% foram quantificaveis, com uma mediana de BPA total de 4,8 ng/mL (4,3 ng/mg de creatinina) e a media geometrica de 4,8 ng/mL (4,7 ng/mg de creatinina).


Assuntos
Humanos , Feminino , Gravidez , Urina , Gravidez/urina , Disruptores Endócrinos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas/métodos , Toxicologia/estatística & dados numéricos , Indústria Alimentícia , Saúde , Cromatografia Gasosa/métodos , Alimentos e Bebidas , Gestantes , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Alimentos
6.
Rev. Hosp. Ital. B. Aires (2004) ; 40(1): 17-24, mar. 2020. ilus
Artigo em Espanhol | LILACS | ID: biblio-1100762

RESUMO

Se estima que aproximadamente 100 trillones de microorganismos (incluidos bacterias, virus y hongos) residen en el intestino humano adulto y que el total del material genético del microbioma es 100 veces superior al del genoma humano. Esta comunidad, conocida como microbioma se adquiere al momento del nacimiento a través de la flora comensal de la piel, vagina y heces de la madre y se mantiene relativamente estable a partir de los dos años desempeñando un papel crítico tanto en el estado de salud como en la enfermedad. El desarrollo de nuevas tecnologías, como los secuenciadores de próxima generación (NGS), permiten actualmente realizar un estudio mucho más preciso de ella que en décadas pasadas cuando se limitaba a su cultivo. Si bien esto ha llevado a un crecimiento exponencial en las publicaciones, los datos sobre las poblaciones Latinoamérica son casi inexistentes. La investigación traslacional en microbioma (InTraMic) es una de las líneas que se desarrollan en el Instituto de Medicina Traslacional e Ingeniería Biomédica (IMTIB). Esta se inició en 2018 con la línea de cáncer colorrectal (CCR) en una colaboración con el Colorectal Cancer Research Group del Leeds Institute of Medical Research en el proyecto Large bowel microbiome disease network: Creation of a proof of principle exemplar in colorectal cancer across three continents. A fines de 2019 se cumplió el objetivo de comprobar la factibilidad de la recolección, envío y análisis de muestras de MBF en 5 continentes, incluyendo muestras provenientes de la Argentina, Chile, India y Vietnam. Luego de haber participado de capacitaciones en Inglaterra, se ha cumplido con el objetivo de la etapa piloto, logrando efectivizar la recolección, envío y análisis metagenómico a partir de la secuenciación de la región V4 del ARNr 16S. En 2019, la línea de enfermedad de hígado graso no alcohólico se sumó a la InTraMic iniciando una caracterización piloto en el marco de una colaboración con el laboratorio Novartis. Los resultados de ese estudio, así como el de cáncer colorrectal, están siendo enviados a publicación. En 2020, con la incorporación de la línea de trasplante alogénico de células progenitoras hematopoyéticas, fue presentado un proyecto para un subsidio del CONICET que ha superado la primera etapa de evaluación. En el presente artículo se brinda una actualización sobre la caracterización taxonómica de microbioma y se describen las líneas de investigación en curso. (AU)


It is estimated that approximately 100 trillion microorganisms (including bacteria, viruses, and fungi) reside in the adult human intestine, and that the total genetic material of the microbiome is 100 times greater than that of the human genome. This community, known as the microbiome, is acquired at birth through the commensal flora of the mother's skin, vagina, and feces and remains relatively stable after two years, playing a critical role in both the state of health and in disease. The development of new technologies, such as next-generation sequencers (NGS), currently allow for a much more precise study of it than in past decades when it was limited to cultivation. Although this has led to exponential growth in publications, data on Latin American populations is almost non-existent. Translational research in microbiome (InTraMic) is one of the lines developed at the Instituto de Medicina Traslacional e Ingeniería Biomédica (IMTIB). This started in 2018 with the Colorectal Cancer Line (CRC) in a collaboration with the Colorectal Cancer Research Group of the Leeds Institute of Medical Research in the project "Large bowel microbiome disease network: Creation of a proof of principle exemplar in colorectal cancer across three continents". At the end of 2019, the objective of verifying the feasibility of collecting, sending and analyzing MBF samples on 5 continents, including samples from Argentina, Chile, India and Vietnam, was met. After having participated in training in England, the objective of the pilot stage has been met, achieving the collection, delivery and metagenomic analysis from the sequencing of the V4 region of the 16S rRNA. In 2019, the non-alcoholic fatty liver disease line joined InTraMic, initiating a pilot characterization in the framework of a collaboration with the Novartis laboratory. The results of that study, as well as that of colorectal cancer, are being published. In 2020, with the incorporation of the allogeneic hematopoietic stem cell transplantation line, a project was presented for a grant from the CONICET that has passed the first stage of evaluation. This article provides an update on the taxonomic characterization of the microbiome and describes the lines of ongoing research. (AU)


Assuntos
Humanos , Pesquisa Translacional Biomédica/organização & administração , Microbioma Gastrointestinal/genética , Transplante Homólogo , Vietnã , Aztreonam/uso terapêutico , RNA Ribossômico 16S/análise , Neoplasias Colorretais/genética , Neoplasias Colorretais/microbiologia , Neoplasias Colorretais/epidemiologia , Classificação/métodos , Transplante de Células-Tronco Hematopoéticas , Metagenômica , Pesquisa Translacional Biomédica/métodos , Sequenciamento de Nucleotídeos em Larga Escala/tendências , Hepatopatia Gordurosa não Alcoólica/genética , Hepatopatia Gordurosa não Alcoólica/microbiologia , Hepatopatia Gordurosa não Alcoólica/patologia , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Microbioma Gastrointestinal/fisiologia , Índia , América Latina , Sangue Oculto
7.
Rev Fac Cien Med Univ Nac Cordoba ; 76(2): 86-91, 2019 06 19.
Artigo em Espanhol | MEDLINE | ID: mdl-31216162

RESUMO

Introduction: Bisphenol A (BPA) is an endocrine disruptor (ED) possibly linked to adverse reproductive and neurodevelopmental effects that is used as an additive in food and beverage containers. There are no data of BPA levels in the Argentine population. The objective of this study was to measure BPA in the urine of pregnant women. Methods: Cross-sectional study. Detection of BPA in pregnant women of the Hospital Italiano de Buenos Aires in 2013, using gas chromatography and mass spectrometry with a limit of quantification of 2 ng / ml and detection of 0.8 ng / ml. The proportion of women exposed to BPA within the 95% confidence interval (IC 95%) is described. Results: 149 pregnant women, average age 32 years (Standard Deviation 5.3), 81% (95% CI 73.9-86.9) workers and 83.7% (95% CI 76.7-89.1) have university or higher education, 66.4% (95% CI 58-74.0) of the urinary samples were quantifiable, with a median BPA of 4.3 ng/mg Cr (RI 3.2-6.7). Conclusions: This study shows that exposure to BPA during the process of embryonic development in a sector of the population of Argentina is widespread. In Argentina, the use of this ED is only regulated in baby bottles.


Introducción: El Bisfenol A (BPA) es un disruptor endócrino (DE) posiblemente vinculado a eventos adversos reproductivos y del desarrollo neurológico que se utiliza como aditivo en envases plásticos de alimentos y bebidas. En la población argentina no existen datos sobre niveles de BPA en orina. El objetivo del estudio fue medir la presencia de BPA en orina de embarazadas. Métodos: Estudio transversal. Detección de BPA en orina de embarazadas atendidas en el Hospital Italiano de Buenos Aires en el año 2013. La técnica utilizada fue cromatografía gaseosa asociada a espectrometría de masa con un límite de cuantificación de 2 ng/ml y de detección de 0,8 ng/ml. Se describe la proporción de mujeres con exposición al BPA con su intervalo de confianza del 95% (IC95%). Resultados: se analizaron 149 muestras de orina de embarazadas de edad promedio 32 años (Desvío Standard 5,3), el 81% (IC95% 73,9-86,9) trabaja y el 83,7% (IC95% 76,7-89,1) posee nivel universitario y/o posgrado.El 66,4% (IC95% 58,2-74,0) de las muestras urinarias presentaron BPA cuantificable, siendo la mediana de BPA de 4,3 ng / mg creatinina (Rango Intercuartilo 3,2-6,7). Conclusiones: Este estudio muestra que la exposición a BPA durante el proceso de formación embrionaria en un sector de la población de Argentina, es generalizada. En Argentina solo está regulado el uso de este DE en mamaderas.


Assuntos
Compostos Benzidrílicos/urina , Disruptores Endócrinos/urina , Exposição Materna/estatística & dados numéricos , Fenóis/urina , Adolescente , Argentina , Estudos Transversais , Feminino , Humanos , Gravidez
8.
Acta bioquím. clín. latinoam ; 52(1): 79-87, mar. 2018. graf, tab
Artigo em Espanhol | LILACS | ID: biblio-886165

RESUMO

El Bisfenol-A (BPA) es ampliamente utilizado en la producción de plásticos de policarbonato, por lo que está presente en productos de uso masivo. Es un disruptor endócrino e incide en el desarrollo gonadal y del sistema nervioso central. La exposición de mujeres embarazadas al BPA es particularmente preocupante para el feto en desarrollo, debido a que atraviesa la placenta pasando a la sangre de cordón y al líquido amniótico. Esto se suma a la escasa o nula actividad enzimática fetal para biotransformarlo en BPA-glucurónido inactivo, causando posibles efectos nocivos a la descendencia a dosis muy bajas y sostenidas. Con el propósito de estudiar la exposición al BPA y sus efectos en la población de Argentina se desarrolló y validó un método analítico por cromatografía líquida acoplada a espectrometría de masa, que permite la cuantificación de trazas de BPA libre (forma estrogénica, activa) en plasma de cordón umbilical. La técnica consiste en la precipitación de proteínas de la sangre de cordón por agregado de acetonitrilo y posterior centrifugado e inyección del sobrenadante. Se utilizó una elución isocrática en la cromatografía líquida, y la espectrometría de masa se realizó empleando Electrospray negativo en modo de monitoreo de reacciones múltiples. Los valores de BPA libre cuantificados están en el rango de 1,0 a 12,1 ng/mL, límite de detección: 0,6 ng/mL.


Bisphenol-A (BPA) is widely used in the production of polycarbonate plastics and therefore, it is present in products of massive use. It is known as an endocrine disruptor and has an impact on gonadal and central nervous system development. Exposure of pregnant women to BPA is particularly worrying for the developing fetus because it crosses the placenta into the cord blood and amniotic fluid, coupled with little or no fetal enzymatic activity to biotransform it into inactive BPA-glucuronide, causing possible harmful effects to the offspring at very low and sustained doses. With the aim to study the exposure to BPA and its effects on the population of Argentina, an analytical method was developed and validated by liquid chromatography coupled to mass spectrometry, which allows the quantification of trace amounts of free BPA (estrogenic, active form) in plasma of umbilical cord. The method involves protein precipitation by the addition of acetonitrile and subsequent centrifugation and injection of supernatant. An isocratic elution was used in liquid chromatography, and mass spectrometry was performed using negative Electrospray mode in multiple reaction monitoring. Quantified free BPA values are in the range of 1.0 to 12.1 ng/mL, Detection Limit: 0,6 ng/mL.


O Bisfenol-A (BPA) é amplamente utilizado na produção de plásticos de policarbonato, portanto está presente em produtos de uso massiço. Ele é um disruptor endócrino e tem um impacto no desenvolvimento gonadal e do sistema nervoso central. A exposição de mulheres grávidas ao BPA é particularmente preocupante para o feto em desenvolvimento, visto que atravessa a placenta passando ao sangue do cordão e ao líquido amniótico Isso é adicionado à pouca ou nula atividade enzimática fetal para biotransformá-lo em BPA-glicuronídeo inativo, o que causa possíveis efeitos nocivos aos descendentes em doses muito baixas e sustentadas. Visando a estudar a exposição ao BPA e seus efeitos na população da Argentina, foi desenvolvido e validado um método analítico por cromatografia líquida acoplada à espectrometria de massa, que permitem a quantificação de vestígios de BPA livre (forma estrogênica, livre) em plasma do cordão umbilical. A técnica consiste na precipitação de proteínas do sangue de cordão por adição de acetonitrila e posterior centrifugação e injeção no sobrenadante. Na cromatografia líquida, foi utilizada uma eluição isocrática, e a espectrometria de massa foi realizada utilizando Electrospray negativo em modo de monitoramento de reações múltiplas. Os valores de BPA livre quantificados estão na faixa de 1,0 a 12,1 ng/mL, limite de detecção: 0,6 ng/mL.


Assuntos
Humanos , Cromatografia Líquida , Disruptores Endócrinos , Sangue Fetal , Espectrometria de Massas , Dieta , Estudos de Avaliação como Assunto
9.
Int J Clin Pharmacol Ther ; 54(10): 825-34, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27049055

RESUMO

OBJECTIVE: To evaluate the relative bioavailability of a new formulation of emtricitabine (EMT) 200 mg and tenofovir disoproxil fumarate (TNF) 300 mg and to compare with reference formulation to meet regulatory criteria in Argentina. METHODS: A randomized-sequence, open-label, twoperiod crossover study was conducted on 24 healthy Caucasian volunteers in a fasting state. A single oral dose of T or R formulations was followed by a 7-day washout period. Samples were collected at baseline, 0.25, 0.50, 0.75, 1, 1.25, 1.5, 2, 2.5, 3, 4, 7, 12, 24, and 48 hours after administration. EMT and TNF were determined by LC-MS/MS. RESULTS: Geometric means (90% CI) Cmax for EMT in test and reference were 1,891.22 (1,777.1 - 2,187.31) and 1,830.31 (1,721.19 - 2,134.01) ng/mL, the AUC0-t were 10,283.07 (9,624.29 - 11,566.34) and 10,518.76 (9,942.79 - 11,578.30) ng × h/mL and the AUC0-∞ were 10,615.14 (9,948.56 - 11,866.26) and 10,804.12 (10,221.04 - 11,864.85) ng × h/mL, respectively. For TNF test and reference, Cmax geometric means (CI range) were 202.91 (187.91 - 255.78) and 212.04 (195.98 - 264.87) ng/mL, AUC0-t were 1,429.96 (1,334.63 - 1,680.00) and 1,420.75 (1,326.76 - 1,622.18) ng × h/mL and AUC0-∞ were 1,657.11 (1,551.60 - 1,921.75) and 1,631.84 (1,523.95 - 1,857.97), respectively. No differences were detected between the formulations. The test/reference ratios (90% CI) for Cmax, AUC0-t, and AUC0-∞ were 103.33% (95.7 - 111.6), 97.76% (93.6 - 102.1), and 98.25% (94.3 - 102.4) for EMT, and 95.70% (85.9 - 106.6), 95.20% (83.4 - 108.6) and 91.10% (80.7 - 102.7) for TNF. CONCLUSIONS: In this single-dose study, the EMT/TNF tablets (test formulation) met the standard 90% CI criterion for bioequivalence with the reference formulation.


Assuntos
Fármacos Anti-HIV/administração & dosagem , Combinação Emtricitabina e Fumarato de Tenofovir Desoproxila/administração & dosagem , Adulto , Fármacos Anti-HIV/farmacocinética , Área Sob a Curva , Argentina , Disponibilidade Biológica , Cromatografia Líquida , Estudos Cross-Over , Combinação Emtricitabina e Fumarato de Tenofovir Desoproxila/farmacocinética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Comprimidos , Espectrometria de Massas em Tandem , Equivalência Terapêutica , Fatores de Tempo , Adulto Jovem
10.
Acta bioquím. clín. latinoam ; 48(2): 243-248, jun. 2014. graf, tab
Artigo em Espanhol | LILACS | ID: lil-734233

RESUMO

La medida de actividad del factor von Willebrand (vWF) es importante para el diagnóstico de la enfermedad de von Willebrand (vWD). El equipo Innovance®vWF Ac (Siemens Healthcare Diagnostics) utiliza un método inmunoturbidimétrico diseñado para coagulómetros Sysmex CA (Siemens). El objetivo del estudio fue desarrollar y validar la metodología del reactivo Innovance®vWF Ac para el coagulómetro ACL TOP 700 (Instrumentation Laboratory, IL) y realizar un estudio comparativo de su desempeño frente a la de la técnica vWF Activity (vWF Act, IL) y a la del cofactor de ristocetina (vWF:RCo) por agregación de transmisión de luz. Se desarrolló, calibró y validó la técnica mediante estudios de verificación de linealidad y precisión total para dos niveles de control. Se midió la actividad del vWF por los métodos Innovance®vWF Ac y vWF Act en 82 muestras consecutivas dentro del rango reportable. Para comparar métodos se utilizó la regresión de Deming. El análisis inicial de los resultados de Innovance®vWF Ac y vWF Act demostró que no eran estadísticamente comparables. Se observó un Bias negativo para Innovance®vWF Ac en muestras con vWF Act>150%. Excluyendo las mismas, se demostró que los resultados de ambas pruebas eran comparables, al igual que los de Innovance®vWF Ac y vWF:RCo en un subgrupo de 27 muestras. La adaptación del método Innovance®vWF Ac en el ACL TOP 700 fue exitosa, presentó linealidad y precisión acorde con los requerimientos de calidad del laboratorio, brindando resultados comparables a los de vWF Act y vWF:RCo en el rango de 5-150%, útil para el diagnóstico de vWD.


Measurement of vonWillebrand factor (vWF) activity is important for the diagnosis of von Willebrand disease (vWD). Innovance®vWF Ac assay was designed to Sysmex CA (Siemens) coagulometer. The aim of the study was to develop and validate a method for Innovance®vWF Ac in the ACL TOP 700 (Instrumentation Laboratory) coagulometer and to compare its performance against vWF Activity assay (Instrumentation Laboratory, vWF Act) and Ristocetin cofactor assay by light transmission aggregation (vWF:RCo). The method was designed, calibrated and validated through verification of linearity and total precision studies at two levels of control plasmas. vWF activity was measured by Innovance®vWF Ac and vWF Act in 82 consecutive samples with vWF Act values within the reportable range. For method comparison, Deming regression was used. The initial analysis of results showed that they were not statistically comparable with a negative Bias with Innovance®vWF Ac in samples with vWF Act>150%. Excluding these samples, Deming regression curve showed that both tests gave statistically comparable results, and also did Innovance®vWF Ac and vWF:RCo in a subset of 27 samples. The adaptation of the Innovance®vWF Ac method on the ACL TOP 700 coagulometer was successful, it met the quality requirements of the laboratory for linearity and accuracy, providing comparable results to vWF Act and vWF:RCo in the of 5-150% range, useful for vWD diagnosis.


Medir a atividade do fator von Willebrand (vWF) é importante para o diagnóstico da doença de von Willebrand (vWD). A equipe Innovance®vWF Ac (Siemens Healthcare Diagnostics) utiliza um método imunoturbidimétrico projetado para coagulômetros Sysmex CA (Siemens). O objetivo do estudo foi desenvolver e validar a metodologia do reagente Innovance®vWF Ac para o coagulômetro ACL TOP 700 (laboratório de instrumentação, IL) e realizar um estudo comparativo do seu desempenho perante a técnica vWF Activity (vWF Act, IL) e a do cofator de ristocetina (vWF:RCo) por agregação de transmissão de luz. A técnica foi projetada, calibrada e validada através de testes de verificação da linearidade e total precisão para dois níveis de controle. Foi mensurada a atividade do vWF pelos métodos Innovance®vWF Ac e vWF Act em 82 amostras consecutivas dentro do intervalo reportável. Para comparar métodos foi utilizada a regressão de Deming. A análise inicial dos resultados da Innovance®vWF Ac e vWF Act demonstrou que eles não eram estatisticamente comparáveis. Observou-se um viés negativo para Innovance®vWF Ac em amostras com vWF Act> 150%. Excluindo as mesmas, foi demonstrado que os resultados de ambos os testes eram comparáveis, do mesmo modo que os Innovance®vWF Ac e vWF:RCo num subgrupo de 27 amostras. A adaptação do método Innovance®vWF Ac no ACL TOP 700 foi bem-sucedida, apresentou linearidade e precisão conforme os requisitos de qualidade do laboratório, fornecendo resultados comparáveis aos vWF Act e vWF:RCo na faixa de 5-150%, útil para o diagnóstico da vWD.


Assuntos
Humanos , Doenças de von Willebrand , Fator de von Willebrand , Fator de von Willebrand/fisiologia , Técnicas de Laboratório Clínico , Complexo Glicoproteico GPIb-IX de Plaquetas , Ristocetina
11.
Acta bioquím. clín. latinoam ; 48(2): 243-248, jun. 2014. graf, tab
Artigo em Espanhol | BINACIS | ID: bin-131573

RESUMO

La medida de actividad del factor von Willebrand (vWF) es importante para el diagnóstico de la enfermedad de von Willebrand (vWD). El equipo Innovance«vWF Ac (Siemens Healthcare Diagnostics) utiliza un método inmunoturbidimétrico diseñado para coagulómetros Sysmex CA (Siemens). El objetivo del estudio fue desarrollar y validar la metodología del reactivo Innovance«vWF Ac para el coagulómetro ACL TOP 700 (Instrumentation Laboratory, IL) y realizar un estudio comparativo de su desempeño frente a la de la técnica vWF Activity (vWF Act, IL) y a la del cofactor de ristocetina (vWF:RCo) por agregación de transmisión de luz. Se desarrolló, calibró y validó la técnica mediante estudios de verificación de linealidad y precisión total para dos niveles de control. Se midió la actividad del vWF por los métodos Innovance«vWF Ac y vWF Act en 82 muestras consecutivas dentro del rango reportable. Para comparar métodos se utilizó la regresión de Deming. El análisis inicial de los resultados de Innovance«vWF Ac y vWF Act demostró que no eran estadísticamente comparables. Se observó un Bias negativo para Innovance«vWF Ac en muestras con vWF Act>150%. Excluyendo las mismas, se demostró que los resultados de ambas pruebas eran comparables, al igual que los de Innovance«vWF Ac y vWF:RCo en un subgrupo de 27 muestras. La adaptación del método Innovance«vWF Ac en el ACL TOP 700 fue exitosa, presentó linealidad y precisión acorde con los requerimientos de calidad del laboratorio, brindando resultados comparables a los de vWF Act y vWF:RCo en el rango de 5-150%, útil para el diagnóstico de vWD.(AU)


Measurement of vonWillebrand factor (vWF) activity is important for the diagnosis of von Willebrand disease (vWD). Innovance«vWF Ac assay was designed to Sysmex CA (Siemens) coagulometer. The aim of the study was to develop and validate a method for Innovance«vWF Ac in the ACL TOP 700 (Instrumentation Laboratory) coagulometer and to compare its performance against vWF Activity assay (Instrumentation Laboratory, vWF Act) and Ristocetin cofactor assay by light transmission aggregation (vWF:RCo). The method was designed, calibrated and validated through verification of linearity and total precision studies at two levels of control plasmas. vWF activity was measured by Innovance«vWF Ac and vWF Act in 82 consecutive samples with vWF Act values within the reportable range. For method comparison, Deming regression was used. The initial analysis of results showed that they were not statistically comparable with a negative Bias with Innovance«vWF Ac in samples with vWF Act>150%. Excluding these samples, Deming regression curve showed that both tests gave statistically comparable results, and also did Innovance«vWF Ac and vWF:RCo in a subset of 27 samples. The adaptation of the Innovance«vWF Ac method on the ACL TOP 700 coagulometer was successful, it met the quality requirements of the laboratory for linearity and accuracy, providing comparable results to vWF Act and vWF:RCo in the of 5-150% range, useful for vWD diagnosis.(AU)


Medir a atividade do fator von Willebrand (vWF) é importante para o diagnóstico da doenþa de von Willebrand (vWD). A equipe Innovance«vWF Ac (Siemens Healthcare Diagnostics) utiliza um método imunoturbidimétrico projetado para coagul¶metros Sysmex CA (Siemens). O objetivo do estudo foi desenvolver e validar a metodologia do reagente Innovance«vWF Ac para o coagul¶metro ACL TOP 700 (laboratório de instrumentaþÒo, IL) e realizar um estudo comparativo do seu desempenho perante a técnica vWF Activity (vWF Act, IL) e a do cofator de ristocetina (vWF:RCo) por agregaþÒo de transmissÒo de luz. A técnica foi projetada, calibrada e validada através de testes de verificaþÒo da linearidade e total precisÒo para dois níveis de controle. Foi mensurada a atividade do vWF pelos métodos Innovance«vWF Ac e vWF Act em 82 amostras consecutivas dentro do intervalo reportável. Para comparar métodos foi utilizada a regressÒo de Deming. A análise inicial dos resultados da Innovance«vWF Ac e vWF Act demonstrou que eles nÒo eram estatisticamente comparáveis. Observou-se um viés negativo para Innovance«vWF Ac em amostras com vWF Act> 150%. Excluindo as mesmas, foi demonstrado que os resultados de ambos os testes eram comparáveis, do mesmo modo que os Innovance«vWF Ac e vWF:RCo num subgrupo de 27 amostras. A adaptaþÒo do método Innovance«vWF Ac no ACL TOP 700 foi bem-sucedida, apresentou linearidade e precisÒo conforme os requisitos de qualidade do laboratório, fornecendo resultados comparáveis aos vWF Act e vWF:RCo na faixa de 5-150%, útil para o diagnóstico da vWD.(AU)

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...